Rehman Plaza, Sanda Khurd, Bund Road, Lahore, Pakistan

Fire Hydrants

Fire Hydrants — REW | Pakistan's Largest Valve Manufacturer Since 1948
REW Signature Product · FH Series

Fire Hydrants

Pillar · Wall · Dry Barrel · Wet Barrel · Up to 200mm

Critical fire protection infrastructure for emergency water supply access. REW fire hydrants are manufactured to BSS 750 standards in cast iron, mild steel and gun metal — trusted by fire departments, DHA, Cantonments and industrial facilities across Pakistan since 1948.

Size Range
Up to 200mm
Pressure Rating
Up to 16 bar
Standards
BSS 750
Body Material
CI · MS · GM
Pillar Type Fire Hydrant
Type 01 · FH-P
Pillar Type Fire Hydrant
Street Fire Fighting · Municipal Fire Protection · Industrial Sites
Wall Type Fire Hydrant
Type 02 · FH-W
Wall Type Fire Hydrant
Building Fire Protection · Industrial Buildings · Warehouses
Dry Barrel Fire Hydrant
Type 03 · FH-DB
Dry Barrel Fire Hydrant
Cold Climate · Underground Installation · Freeze Protection
Wet Barrel Fire Hydrant
Type 04 · FH-WB
Wet Barrel Fire Hydrant
Warm Climate · Quick Access · Multiple Outlet
REF · FH-2026
ISO 9001:2015 Certified
BSS 750 Compliant
100% Pressure Tested
Since 1948 · Lahore, Pakistan
79+ Years of Valve Engineering
ISO 9001:2015 Certified
BSS 750 Compliant
100% Pressure Tested
Since 1948 · Lahore, Pakistan
79+ Years of Valve Engineering
Fire Hydrant Cross-Section
CROSS-SECTION · 01
Product Overview

Critical Fire Protection Infrastructure

Fire hydrants are critical emergency water supply access points for firefighting operations. REW fire hydrants provide reliable, high-flow water access for fire departments and emergency response teams — manufactured to BSS 750 standards in cast iron, mild steel and gun metal.

Since 1948, REW has been supplying fire hydrants to fire departments, DHA, Cantonments, industrial facilities and municipal corporations across Pakistan — ensuring reliable fire protection infrastructure for communities and industries.

Emergency Access
Quick water access for firefighting operations
High Flow Capacity
High-flow design for maximum water delivery
Durable Construction
Cast iron, MS and gun metal construction
BSS 750 Standard
Manufactured to British Standard specifications
Product Variants

Four Core Configurations

Each engineered for specific fire protection requirements — from street hydrants to building-mounted and cold-climate installations.

Pillar Type Fire Hydrant
FH-P Type 01
Pillar Type Fire Hydrant
Above-ground pillar type fire hydrant for street and municipal fire protection. Provides multiple outlet connections for fire hose connections. Cast iron or gun metal construction for durability in outdoor environments.
Above-ground pillar installation
Multiple outlet connections
Cast iron or gun metal construction
Weather-resistant outdoor design
Size: Up to 200mm Pressure: Up to 16 bar Material: CI, Gun Metal Standard: BSS 750
Primary Applications
Street Fire Fighting Municipal Industrial Sites DHA
Request Quote
Wall Type Fire Hydrant
FH-W Type 02
Wall Type Fire Hydrant
Wall-mounted fire hydrant for building fire protection systems. Compact design for mounting on building walls, warehouses and industrial buildings. Provides quick access to water supply for firefighting.
Wall-mounted installation
Compact design for buildings
Quick access for firefighting
Suitable for warehouses
Size: Up to 200mm Pressure: Up to 16 bar Material: CI, MS Standard: BSS 750
Primary Applications
Building Fire Protection Warehouses Industrial Buildings Commercial
Request Quote
Dry Barrel Fire Hydrant
FH-DB Type 03
Dry Barrel Fire Hydrant
Dry barrel design with underground valve body for cold climate applications. The valve is located below ground level to prevent freezing. Ideal for regions with freezing temperatures.
Underground valve body
Freeze protection design
Cold climate applications
Drainage feature for freeze protection
Size: Up to 200mm Pressure: Up to 16 bar Material: CI, MS Standard: BSS 750
Primary Applications
Cold Climate Underground Freeze Protection Municipal
Request Quote
Wet Barrel Fire Hydrant
FH-WB Type 04
Wet Barrel Fire Hydrant
Wet barrel design with water-filled barrel for warm climate applications. Multiple outlet connections for simultaneous hose connections. Quick access design for emergency firefighting.
Water-filled barrel design
Multiple outlet connections
Warm climate applications
Quick access for emergency
Size: Up to 200mm Pressure: Up to 16 bar Material: CI, Gun Metal Standard: BSS 750
Primary Applications
Warm Climate Quick Access Multiple Outlet Municipal
Request Quote
Manufacturing Process

Watch Our Production Line

From raw casting to final pressure testing — witness seven decades of valve engineering mastery in motion.

REW Manufacturing Facility

REW Fire Hydrant Manufacturing

From casting to final testing — complete production process

Applications

Serving Fire Protection Across Pakistan

REW fire hydrants protect Pakistan's most critical infrastructure — from municipal fire departments to industrial facilities.

01
Fire Departments
Municipal fire departments, fire stations, emergency response
02
DHA & Cantonments
DHA, Cantonment Boards, military installations
Industrial Facilities
Factories, warehouses, industrial complexes
04
Municipal Corporations
Municipal fire protection, street hydrants
05
Sugar Mills
Sugar mill fire protection systems
06
Oil & Gas
Refineries, oil terminals, gas facilities
07
Power Generation
Power plant fire protection systems
08
Textile Mills
Textile mill fire protection systems
Working Principle

Emergency Water Access

Step-by-step operation of a REW fire hydrant — from connection to water flow for firefighting.

Fire Hydrant Technical Drawing
01
Connection
Fire hose is connected to the hydrant outlet nozzle. The hydrant is connected to the underground water main supply.
02
Valve Opening
Hydrant operating nut is turned with hydrant wrench to open the underground valve. Water flows from main to hydrant.
03
Water Flow
High-pressure water flows through the hydrant to the connected fire hose. Multiple outlets allow simultaneous hose connections.
04
Firefighting
Firefighters use the high-pressure water supply for firefighting operations. Hydrant provides reliable water access.
05
Valve Closing
After firefighting, hydrant valve is closed. Water drains from barrel (dry barrel type) to prevent freezing.
06
Ready for Next Use
Fire Hydrant Construction
CONSTRUCTION VIEW
Construction Details

Every Component Engineered

Detailed breakdown of each major component — function, material, and engineering importance.

Body
Primary pressure-containing component. Cast in CI, MS or Gun Metal. Houses the valve mechanism.
Valve Mechanism
Underground valve controls water flow from main to hydrant. Operated by hydrant wrench.
Outlet Nozzles
Multiple outlet connections for fire hose connections. Standard hose thread connections.
Operating Nut
Pentagon-shaped operating nut for hydrant wrench operation. Standard pentagon shape for security.
Drain Valve
Drain valve for dry barrel hydrants. Drains water from barrel to prevent freezing in cold climates.
Barrel
Above-ground barrel section. Cast iron construction for durability. Multiple outlet connections.
Technical Specifications

The Engineering Ledger

Complete specification sheet for REW Fire Hydrants — every dimension, material, and standard documented.

Fire Hydrant · Full Specification
DOC · FH-SPEC-2026
Product NameFire Hydrant — Pillar, Wall, Dry Barrel, Wet Barrel Types
Size RangeUp to 200 mm
Pressure RatingUp to 16 bar
Body MaterialCast Iron, Mild Steel, Gun Metal
Valve TypePillar, Wall, Dry Barrel, Wet Barrel
End ConnectionFlanged, Threaded
Operating MechanismHydrant Wrench (Pentagon Nut)
Design StandardBSS 750
Testing StandardHydrostatic Pressure Test
ApplicationsFire Protection, Municipal, Industrial, DHA, Cantonments
CertificationISO 9001:2015 · ISO 14001:2015 · ISO 45001:2018 · PSQCA
OriginManufactured in Lahore, Pakistan — Since 1948
Engineering Standards

Compliance & Certifications

Every REW fire hydrant is manufactured and tested to internationally recognized standards.

BSS 750
British Standard
British Standard Specification for fire hydrants. Primary design standard for REW fire hydrants.
ISO 9001:2015
Quality Management
Quality management system certified by TÜV Austria. Every hydrant traceable from raw material to final test.
PSQCA
Pakistan Standards
Pakistan Standards Quality Control Authority certification for quality assurance.
Pressure Ratings

Working & Test Pressures

Pressure ratings for REW fire hydrants.

Pressure ClassWorking Pressure (bar)Test Pressure (bar)
StandardUp to 1624
Fire Hydrant Dimensional Drawing
Dimensional Information

Size & Weight Data

Dimensional data for REW fire hydrants. All dimensions in millimeters.

Size RangeUp to 200 mm
Pressure RatingUp to 16 bar
Body MaterialCI, MS, Gun Metal
StandardBSS 750
The Forge

Forged with 79 Years of Mastery

From raw casting to final pressure testing — every REW fire hydrant passes through a rigorous manufacturing process refined over seven decades at our Lahore facility.

01
Pattern & Casting
Precision wooden/metal patterns, green-sand casting in CI, MS, Gun Metal
02
CNC Machining
CNC machining for valve body, outlet nozzles and operating mechanism
03
Assembly
Assembly of valve mechanism, outlet nozzles and operating nut
04
Pressure Testing
Hydrostatic pressure testing to ensure leak-free performance
05
Painting & Dispatch
Painting, marking, documentation pack with test certificate
REW Manufacturing Facility
FACILITY · LHR
Manufacturing · Lahore Plant
Quality Assurance

Zero-Defect Philosophy

Every hydrant undergoes rigorous inspection and testing before dispatch. Our quality system is certified to ISO 9001:2015 by TÜV Austria.

Incoming Inspection
Raw material verification — chemical composition and mechanical properties
Dimensional Inspection
Precision instruments verify all critical dimensions against approved drawings
Pressure Testing
Hydrostatic pressure testing to ensure leak-free performance
Visual Inspection
Surface finish, casting quality, assembly integrity
Documentation
Test certificates, dimensional reports — complete traceability
REW Quality Assurance Laboratory
QA LAB · LHR
Technical Resources

Download Documentation

Complete technical documentation for engineering, procurement, and installation teams.

Technical Datasheet
Complete specifications, materials, dimensions for all fire hydrant variants.
PDF · Updated 2026
Download →
Product Catalogue
Full REW product range with technical data and ordering information.
PDF · 2026 Edition
Download →
CAD Drawings
2D and 3D CAD files for integration into your designs.
DWG/STEP · All sizes
Download →
Certificates
ISO 9001, ISO 14001, ISO 45001, PSQCA certificates.
PDF · Certified copies
Download →
Installed Projects

Trusted Across Pakistan

REW fire hydrants installed in critical fire protection projects nationwide.

Municipal Fire Protection
Municipal
Lahore Municipal Fire Protection
Lahore, Punjab
100+
Hydrants Installed
2024
Completion
Industrial Fire Protection
Industrial
Industrial Complex Fire Protection
Punjab, Pakistan
50+
Hydrants Supplied
2025
Completion
Technical FAQ

Engineering Questions

Answers to the most common technical questions about REW fire hydrants.

What are the different types of fire hydrants REW manufactures?+
REW manufactures four types: (1) Pillar Type — above-ground for street fire fighting, (2) Wall Type — wall-mounted for building fire protection, (3) Dry Barrel Type — underground valve for cold climate freeze protection, (4) Wet Barrel Type — water-filled barrel for warm climate quick access.
What is the size range for REW fire hydrants?+
REW manufactures fire hydrants up to 200mm diameter. Custom sizes available on request.
What standards do REW fire hydrants comply with?+
REW fire hydrants are manufactured to BSS 750 (British Standard Specification) standards. Quality management certified to ISO 9001:2015 by TÜV Austria.
What materials are available for fire hydrants?+
Standard body materials include Cast Iron, Mild Steel, and Gun Metal. Material selection based on application requirements and environmental conditions.
What is the difference between dry barrel and wet barrel hydrants?+
Dry barrel hydrants have the valve located below ground level — water drains from barrel after use to prevent freezing. Ideal for cold climates. Wet barrel hydrants have water-filled barrel — ready for immediate use. Ideal for warm climates.
What documentation is provided with each shipment?+
Standard documentation includes: Test Certificate, Dimensional Report, and Certificate of Compliance. Third-party inspection certificates available on request.
Can REW manufacture custom fire hydrants?+
Yes. REW can manufacture fire hydrants in custom sizes, custom configurations, and special materials. Custom drawings delivered within 48 hours of specification confirmation.
How do I request a quotation for fire hydrants?+
Submit your requirements via the quote form on this page, email rewpak@yahoo.com, or call +92 322 276 2222. Include: size, type, material, quantity, and application details. Technical team responds within 24 hours.
ISO 9001:2015
Quality Management · TÜV Austria
ISO 14001:2015
Environmental Management
ISO 45001:2018
Health & Safety Management
PSQCA Mark
Pakistan Standards Certified
Request a Quote

Specify Your Fire Hydrant Requirement

Share your size, type, material and quantity — our technical team will respond with specifications, lead time, and competitive pricing within 24 hours.

Quick Quote Request